All steel immersed in seawater corrodes. On a ship, this means the hull, rudder, propeller, sea chests and ballast tanks losing thickness every day the vessel is in the water. Coating is the first barrier, but no coating stays perfect for long: a scratch, a worn area or an application defect is enough to leave steel exposed. Cathodic protection is the second barrier, and it protects the steel precisely where the coating has failed.
MCP Marine supplies, installs and maintains cathodic protection systems on ships, FPSOs, platforms and offshore support vessels, on K.C. LTD, Cathelco, Wilson Walton/Corrpro and any other manufacturer’s systems.
Corrosion is an electrochemical reaction: the hull steel gives up electrons to the seawater and turns into oxide. Cathodic protection reverses this process. It supplies electrons to the hull from another source, so the steel works as a cathode and stops losing metal. The component that wears away becomes another one: the anode.
There are two ways to supply this current:
Many ships use both: ICCP on the hull and galvanic anodes in areas the ICCP current does not reach well, such as sea chests, thruster tunnels and tanks. We compare both solutions in detail in ICCP or sacrificial anodes: which to choose.
We supply complete impressed current cathodic protection systems with titanium anodes coated with mixed metal oxides (Ti-MMO), manufactured by K.C. LTD, a global reference in anti-corrosion engineering. The KCIG series automatic control panels cover systems from 100 A to 1,000 A, and K.C. LTD Ti-MMO anodes have a service life of at least 15 years.
A hull ICCP system has five parts that must work together:
On larger ships, it is common to have one system forward and another aft, so the current reaches the whole hull.
Technical advantages: – Long-lasting, low-maintenance anodes – Compatibility with existing systems – Installation without major structural work, avoiding long downtime or operational risk – Supply with technical support for installation and commissioning
These features make ICCP ideal for upgrading and reactivating cathodic protection, even on assets in operation. Recovering an existing system often costs less than replacing it.
We offer a complete range of sacrificial anodes in aluminium, zinc and magnesium alloys to protect hulls, rudders, propellers, tanks and immersed steel structures. Anodes are sized according to the vessel’s electrochemical profile and the water it operates in: seawater, fresh water or brackish water.
The goal of cathodic protection is a potential range. The hull must stay within it: neither under-protected nor over-protected. Both extremes are defects.
The DNV-RP-B401 recommended practice, the international reference for cathodic protection design, adopts -0.80 V versus the silver/silver chloride (Ag/AgCl) electrode as the reference protection potential for carbon steel in seawater. In operation, the reading depends on the type of sensor installed on the ship. This is the table MCP Marine uses in the field to assess the hull:
| Zinc (Zn) sensor | Condition | Silver/silver chloride (Ag/AgCl) sensor |
|---|---|---|
| +350 mV or more positive | Under-protection | -700 mV or more positive |
| +300 to -100 mV | Normal protection range | -750 to -1,150 mV |
| -150 mV or more negative | Over-protection | -1,200 mV or more negative |
The reading rule is the same for both: the more negative, the more protected; the more positive, the less protected.
The fixed ICCP sensors only measure the point where they are installed. That is why, during inspections, MCP Marine also measures the potential with a portable reference electrode, lowered into the water every 30 to 40 metres along the entire hull. This shows whether protection reaches the whole hull and whether the fixed sensors are reading correctly.
An ICCP system rarely fails all at once. In most cases, the problem first shows up in the numbers the crew logs every day, if you know what to look for:
A simple test helps tell a healthy anode from a faulty one: the current of a healthy anode follows the voltage proportionally. On a 100 A panel with two anodes, for example, each anode delivers up to 50 A: at half the output voltage, the current should be close to half; at full voltage, close to the maximum. If the voltage rises and the current does not follow, there is a problem.
Ships that sail up rivers or operate in estuaries face a harder situation. Fresh water conducts much worse than seawater: the ICCP needs more voltage to deliver the same current, the current reaches shorter distances and the sensor readings change. Aluminium and zinc anodes also lose efficiency in fresh water. On these ships, the ICCP operating point and the choice of anode alloys need careful assessment. We show a real case in River-sea navigation: what hull coating and ICCP reveal at dry dock.
The current generated by cathodic protection systems can stray and flow through the propulsion system, causing severe damage when shaft earthing is undersized or poorly installed.
Common problems: – Wear at the propeller blade tips from cavitation or galvanic erosion – Material loss in bearings from current flowing through the shaft-bearing contact – Electrical discharges through seawater between propeller and hull, creating a low-resistance path for the current
Earthing devices supplied by engine manufacturers often do not provide adequate protection against this phenomenon. That is why MCP Marine offers technical assessment, specialist guidance and full support for the correct sizing and installation of shaft earthing.
Every MCP Marine ICCP service follows the same logic, so results can be compared from one year to the next:
On ships with forward and aft systems, the same procedure is repeated for each panel.
This service is available as: – Annual review of ICCP and MGPS, with the vessel in operation (4 days on average, including boarding and disembarking) – Preventive and corrective maintenance and inspection – Dry-docking services: inspection of anodes, sensors and dielectric shields, component replacement and commissioning – ICCP repair and anode replacement by diving, without dry-docking, with a certified partner diving team
It is the technique that prevents corrosion of the hull steel by supplying it with an electric current, through galvanic anodes or an impressed current system (ICCP). With protection, the hull stops losing metal even where the coating has failed.
Sacrificial anodes are consumed on their own and do not adjust. ICCP uses inert anodes and a panel that adjusts the current automatically according to sensor readings. On medium and large ships, ICCP usually has a lower lifetime cost. See the full comparison.
Yes. Over-protection disbonds the coating and may embrittle high-strength steels. The goal is to keep the hull within the protection range, neither above nor below.
Follow the panel’s daily readings (sensor potential, output voltage and current) and watch for inconsistent combinations, such as a poorly protected hull with low current. Confirmation comes from a survey with a portable electrode along the hull and from manual and automatic mode tests.
We recommend a full annual review, which also supports the classification society’s periodic survey, plus inspection of the external components at every dry-docking.
Yes. We service K.C. LTD, Cathelco, Wilson Walton/Corrpro and any other manufacturer’s ICCP and MGPS systems.
Need to assess, reactivate or upgrade the cathodic protection of your ship or offshore unit? WhatsApp +55 21 99512-0824 · +55 21 2088-8137 · info@mcpmarine.com.br
Read also: ICCP or sacrificial anodes: which to choose · River-sea navigation: hull coating and ICCP · MGPS: how it works and 7 warning signs

















R. Expedicionário Ari Rauen, 284 – Colubandê
São Gonçalo – RJ, 24744-150, Brazil